@article { author = {Ostadimoghddam, H and Sharifi, F and Azimi, A and Yekta, A.A and SAlehabadi, A and Ghasemzadeh, T}, title = {Effect of induced refractive errors on measurement of color vision by using D15 test}, journal = {Journal of Paramedical Sciences & Rehabilitation}, volume = {2}, number = {1}, pages = {7-11}, year = {2013}, publisher = {Mashhad University of Medical Siences}, issn = {2322-5238}, eissn = {2345-2730}, doi = {10.22038/jpsr.2013.497}, abstract = {Purpose: To evaluate the effect of Hyperopia, Myopia and Astigmatism on measurement of color vision, we experimentally induced refractive errors by positive, negative and cylinder lenses and estimated this effect on measurement of color vision. Methods: From one hundred patients referred to optometry clinic, sixty subjects with distance corrected or uncorrected visual acuity of 6.6, and without any ocular pathology were selected. Color vision was measured by D15 test before and after introducing 2 to 14 diopter positive lenses, 4 to18 diopter minus lenses and 2 to 10 diopter positive cylinder lenses, to induce Hyperopia, myopia and astigmatism respectively. Results: The age was between 15 to 45 years. Although the decrease in color vision (or increase in the mean errors) was significant by introducing 4 to 14 positive, 8 to 18 minus and  4 to 10 cylinder, but it was not statistically significant by introducing 3 D positive lenses ,3D cylinder lenses and 4 D minus lenses.  Conclusion: Induced 4 D or more myopia and astigmatism reduces color vision measured by D-15 test. But induced 8D or more Hyperopia can cause reduction in color vision measurement? On the other hand myopia and astigmatism less than 4 diopters, and hyperopia less than 8 diopters have no effect on the measurement of color vision. }, keywords = {refractive error,Color vision,D15 test}, title_fa = {بررسی اثر دوربینی، نزدیک بینی و آستیگماتیسم تجربی بر اندازه گیری دید رنگ توسط تست D-15}, abstract_fa = {هدف: امروزه دید رنگ و اندازه گیری آن از اهمیت ویژه ای برخوردار است. نظر به اینکه عیوب انکساری می توانند اختلالاتی در اندازه گیری دید رنگ ایجاد کنند، برای بررسی ابعاد این تاثیر بر آن شدیم کهتاثیر عیب انکساری ایجاد شده تجربی توسط عدسیهای مثبت، منفی وسیلندر را بر روی اندازه گیری دید رنگ مورد مطالعه قرار دهیم. روش بررسی: از بین 100 نفر از بیماران مراجعه کننده به کلینیک بینایی سنجی 60 نفر با توجه به معیارهای خروجی (نداشتن مشکل ته چشمی، نداشتن سابقه خانوادگی کوررنگی، عدم استفاده از داروهای موثر بر چشم، نداشتن عیب انکسار بیشتر از 2 دیوپتر و... ) مورد معاینه قرار گرفتند. برای ایجاد هایپروپی از لنزهای مثبت 2 تا 14 دیوپتر و برای ایجاد میوپی از لنز های منفی 4 تا 18 دیوپتر  و برای ایجاد  آستیگمات از عدسی های سیلندر مثبت2 تا 10 دیوپتر، با استپ 2 دیوپتر استفاده گردید و برای اندازه گیری دید رنگ، تست D-15  استفاده شد. یافته ها : میانگین سنی افراد مورد مطالعه بین 15 تا 45 بود. با افزایش مقدار عدسی میانگین خطا در هر سه گروه افزایش می یابد (p=00/0). این افزایش برای مایوپی با عدسی های4+ تا 14+ به ترتیب 1/17، 3/13، 6/25، 9، 11/2 و 13 می باشد. در هایپروپی ایجاد شده این افزایش با عدسی های 8- تا 18- به ترتیب 1/88، 4/82، 7/88، 10/05، 11/77 و 13/27 می باشد و در مورد آستیگمات ایجاد شده این افزایش با عدسی های 4+ تا 10+ به ترتیب72/0، 2/75، 6/57 و 8/55   می باشد. بحث و نتیجه گیری: مایوپی 4 دیوپتر و بیشتر، آستیگمات 4 دیوپتر و بیشتر (در محور 45 درجه) و هایپروپ 8 دیوپتر و بیشتر باعث ایجاد خطا در چیدن مهره های رنگی تست D-15 می شود. لذا اصلاح عیوب انکساری با مقادیر ذکر شده قبل از اندازه گیری دید رنگ لازم و ضروری به نظر می رسد.}, keywords_fa = {عیوب انکساری,دید رنگ,تست دید رنگ D-15}, url = {https://jpsr.mums.ac.ir/article_497.html}, eprint = {https://jpsr.mums.ac.ir/article_497_ce0e917df92b6563216cbd79790da476.pdf} } @article { author = {Mohammadian, M and Jafarzadehpur, E and Mirzajani, A and Jabarvand Behrouz, M and Khabazkhoob, M}, title = {Comparison of OCT pachymetry pattern in Keratoconus suspect and normal subjects}, journal = {Journal of Paramedical Sciences & Rehabilitation}, volume = {2}, number = {1}, pages = {12-16}, year = {2013}, publisher = {Mashhad University of Medical Siences}, issn = {2322-5238}, eissn = {2345-2730}, doi = {10.22038/jpsr.2013.495}, abstract = {Purpose: Comparison of pachymetry pattern of OCT finding in Keratoconus (KCN) suspect and normal subjects. Methods: Thirty-two KCN suspect eyes and Thirty- eight normal eyes in young subjects (20-30 year- old) were evaluated. Pachymetry pattern of frequency domain OCT (Visante) in different parts of cornea (thinnest point, inferior – superior thickness difference, inferior temporal – superior nasal thickness difference and thinnest point in 0-2 millimeter decent ration) were measured. Results: There was a significant (p<0.0001) difference in normal and KCN suspect patients in all measurements. KCN suspects showed thinner cornea and more differences in corneal thickness measurements. Conclusion: Anterior frequency domain OCT seems to be suitable for evaluation of KCN suspect patients. It may be critical for refractive surgery candidate and may be used as Pentacam or OrbScan corneal imaging systems.}, keywords = {Keratoconus,Optical coherence tomography,KCN suspect,Pachymetry}, title_fa = {مقایسه الگوی پاکیمتری OCT در افراد مشکوک به کراتوکونوس و افراد نرمال}, abstract_fa = {هدف: مقایسه الگوی پاکیمتری OCT افراد مشکوک به قوز قرنیه و افراد نرمال روش بررسی: 32 چشم مشکوک به کراتوکونوس و 38 چشم سالم در محدوده سنی 20-30 سال انتخاب شدند. الگوی پاکیمتری آنان با دستگاه OCT ویزانته در نازکترین نقطه، تفاوت فوقانی تحتانی قرنیه (I-S)، تفاوت ضخامت تمپورال تحتانی و نازال فوقانی (IT-SN) و خروج و یا عدم خروج نازکترین محل قرنیه از منطقه 2-0 مرکزی با استفاده از نقشه خروجی استخراج گردید . یافته ها: در تمامی پارامترهای اندازه گیری شده تفاوت معنی داری (0/0001>p) در نتایج دو گروه مشاهده گردید. افراد مشکوک به کراتوکونوس، قرنیه نازک تر و تغییرات ضخامت بیشتری را نسبت به گروه نرمال نشان دادند. بحث و نتیجه گیری: به نظر می رسد می توان ازسیستم OCT سگمان قدامی جهت ارزیابی بیماران قبل از جراحی انکساری و یا اسکرینینگ قوز قرنیه در کنار دستگاههایی چون پنتاکم و ارب اسکن بهره برد.}, keywords_fa = {قوز قرنیه,OCT,پاکیمتری}, url = {https://jpsr.mums.ac.ir/article_495.html}, eprint = {https://jpsr.mums.ac.ir/article_495_f08c0550fc090915ab5cc07e1ca6f6c0.pdf} } @article { author = {Azimi, A and Heravian, J and Emadzadeh, A and Masihpoor, N and Ghanbari Gelehdari, M and Tajodini, F and Mahjoob, M and Hosseini Yazdi, H}, title = {Evaluation of depth perception and heterophoria among laboratory sciences students in Mashhad, 2011}, journal = {Journal of Paramedical Sciences & Rehabilitation}, volume = {2}, number = {1}, pages = {17-21}, year = {2013}, publisher = {Mashhad University of Medical Siences}, issn = {2322-5238}, eissn = {2345-2730}, doi = {10.22038/jpsr.2013.503}, abstract = {Purpose: Normal stereopsis as the highest level of binocular vision is required for most of clinical works such as working with microscope and some jobs, like piloting and surgery. The aim of this study was to evaluate, depth perception and hetrophoria in Mashhad laboratory sciences students in 2011. Methods: In this cross sectional study from 153 Mashhad laboratory sciences students, 42 subjects were selected randomly. Eye examinations including subjective and objective refraction and measurement of hetrophoria by cover test and prism bar were performed. The stereopsis was then determined with the T.N.O stereo test at 40 distance observation. Data were analyzed using SPSS version 11.5 software. Patients with amblyopia, cataract, and other ocular pathology were excluded from the study. Results: Mean stereoacuity of the subjects was 147/14 129/76. Among this population, 14 subjects (%33.3) used microscope monocularly and 28 subjects (% 66.7) used it bionocularly. There was no significant difference between mean stereopsis and  hetrophoria and other relative effective factors such as refractive error, way of using microscope, near point of convergence age and sex (p>0.05). Comparison between mean monocular and binocular stereopsis was not significant (p>0.05).  Conclusion: There was no statictically significant difference between mean stereopsis and hetrophoria and other relative factors. However due to working too much with microscope, most of the laboratory sciences students had anomaly of binocular vision like intermittent exotropia and abnormal near point of convergence. This indicates the necessity of more research in anomaly of binocular vision in laboratory sciences students. }, keywords = {Stereopsis,Heterophoria T.N.O. Stereotest}, title_fa = {بررسی دید عمق و هترفوریا در دانشجویان علوم آزمایشگاهی مشهد درسال 1390}, abstract_fa = {هدف: تعیین دید عمق و هتروفوریا در دانشجویان علوم آزمایشگاهی مشهد روش بررسی: در این مطالعه مقطعی از بین153 نفر دانشجویان علوم آزمایشگاهی دانشگاه علوم پزشکی مشهد تعداد 42 نفر بطور تصادفی برای این پژوهش انتخاب گردیدند. معاینات چشمی شامل تعیین عیب انکسار به روش ابجکتیو و سابجکتیو و بررسی هتروفوریا  با استفاده از کاور تست و پریزم و اندازه گیری دید عمق با استفاده از تست TNO در فاصله 40 سانتی متری بود. سپس نتایج و داده ها با استفاده از نرم افزار spss  ورژن 11/5  مورد آنالیز قرار گرفت. افراد با امبلیوپی و کاتارکت و سایر بیماریهای چشمی از مطالعه خارج شدند. یافته ها: میانگین دید عمق دانشجویان  766/129± 14/147(ثانیه بر قوس) بود. از این تعداد 14 نفر 33/3درصد به صورت تک چشمی و 28 نفر 66/7 درصد به صورت دو چشمی با میکروسکوپ کار می کردند. بین میانگین دید عمق و هتروفوریا و همچنین سایر موارد شامل، نحوه کار با میکروسکوپ،، نقطه نزدیک تقارب وجنسیت اختلاف معنی داری مشاهده نشد ( 0/050.61). In relation to the total score, all of the tools Intra-class correlation coefficients were more than 0.9. The questionnaires reliability coefficients (internal consistency) were calculated 0.83-0.93. Item-total correlation confirmed their reliability too. Their concurrent validity with Persian Original Barthel index were confirmed (r=0.98, p<0.0001). The known-groups approach also revealed that these tools are valid (p<0.0001). Conclusion: The Persian versions of short 3, 4 and 5- item Barthel index for evaluation of disability in elderly, residing in Golabchi nursing home are valid and reliable.}, keywords = {Barthel index,Reliability,Validity,Geriatric,Disability,Nursing home}, title_fa = {روانسنجی فرمهای کوتاه مقیاس بارتل در سالمندان مقیم خانه سالمندان}, abstract_fa = {هدف: ارزیابی مداوم سطح توانمندی سالمندان مقیم خانه سالمندان در انجام عملکرد روزمره ضروری است. به نظر می رسد یکی از ویژگیهای مهم ابزارهای مناسب، فرمهای کوتاه پرسشنامه می باشد. این مطالعه با هدف بررسی روایی و پایایی نسخه 3،4 و 5 سوالی مقیاس بارتل در سالمندان مقیم خانه سالمندان طراحی شده است. روش بررسی: پس از ترجمه ابزارها، نمونه ها به صورت سرشماری در مرکز سالمندان گلابچی کاشان در سال 1386 انتخاب شدند (n=100 ). داده ها بوسیله مشاهده و مصاحبه جمع آوری گردید. ضریب توافق بین افراد ارزیاب بررسی شد. پایایی پرسشنامه ها با استفاده از شیوه ثبات داخلی تعیین گردید. جهت تعیین روایی ابزارها از شیوه روایی همزمان و مقایسه گروههای شناخته شده، استفاده شد. اطلاعات با استفاده از ضریب همبستگی پیرسون، ضریب همبستگی درون طبقه ای(ICC)، کاپا، آلفای کرونباخ و آزمون کروسکال والیس مورد تجزیه و تحلیل قرار گرفت. یافته ها: ضریب توافق بین افراد ارزیاب در ارتباط با هر یک از گویه ها در کلیه ابزارهای مورد بررسی در حد خوب گزارش شد (0/61 > کاپا)؛ ICC در ارتباط با کل هر یک از مقیاسها بیش از 0/9 بود. ضریب ثبات داخلی ابزارهای مورد نظر 0/93-0/83 محاسبه شد. روش همبستگی هر سوال با نمره کل  نیز کلیه فرمهای کوتاه را پایا تشخیص داد. اعتبار همزمان آنها بانسخه فارسی OBI تایید ش  (p<0/0001 , r=0/98 )؛ مقایسه گروههای شناخته شده نیز روایی ابزارها را مسجل ساخت (0/0001>p). بحث و نتیجه گیری: ترجمه فارسی فرمهای کوتاه 3،4و5 سوالی پرسشنامه  بارتل جهت سنجش ناتوانی در عملکرد روزانه در سالمندان مقیم خانه سالمندان گلابچی کاشان ابزاری روا و پایا می باشند.}, keywords_fa = {پرسشنامه بارتل,اعتبار,پایایی,ناتوانی,سالمند,خانه سالمندان}, url = {https://jpsr.mums.ac.ir/article_493.html}, eprint = {https://jpsr.mums.ac.ir/article_493_9cf47266ae8acfbd48bc309426f38f8e.pdf} } @article { author = {Sheikh, M and Bahrpeyma, F and Ebrahimi, I and Forogh, B and Hosseini, HA and Ravari, M}, title = {Study the effect of “constraint-induced movement therapy “on symmetry of spatiotemporal gait parameters in hemiparetic patients}, journal = {Journal of Paramedical Sciences & Rehabilitation}, volume = {2}, number = {1}, pages = {39-48}, year = {2013}, publisher = {Mashhad University of Medical Siences}, issn = {2322-5238}, eissn = {2345-2730}, doi = {10.22038/jpsr.2013.502}, abstract = {Purpose: Balance and gait disorders are common motor complications after stroke. Studies have revealed that conventional physiotherapy cannot manage these disorders efficiently, so more studies addressing causes of these complications and presenting efficient treatment protocols are crucial. Concerning the significant effect of Constraint Induced Movement Therapy on treatment of upper limbs motor impairments in hemiparetic patients, the goal of this study is to assess the effect of “Constraint Induced Movement Therapy” on symmetry of spatiotemporal gait parameters and velocity of gait in hemiparetic patients. Methods: Thirty hemiparetic patients (aged from 40 to 60 years) participated in this study. Patients were divided randomly into 2 groups. They received constraint induced movement therapy (group1) and mass practice (group 2) for 3 weeks. Experimental assessments of patients included stride velocity and symmetry of spatiotemporal gait parameters (spatial step symmetry, temporal stance symmetry, temporal swing asymmetry, overall temporal asymmetry) that were recorded and compared before and after treatment. In addition, the amount of weight bearing asymmetry was assessed via dual force platform. Results: In both groups, stride velocity increased (p=0.03, p=0.01). In group A, spatial step symmetry increased (p=0.02).Temporal swing asymmetry and overall temporal asymmetry decreased (p=0.01). In group B, only temporal swing asymmetry decreased (p=0.02). Conclusion: Physical therapy by “constraint induced movement therapy” can improve symmetry of spatiotemporal gait parameters efficiently through overcoming the “learned non use “phenomenon and improving the somatosensory deafferentation to motor controller centers.}, keywords = {Constraint-induced movement therapy,Gait,Spatiotemporal parameters,Hemiparesis}, title_fa = {بررسی تاثیر " حرکت درمانی بر اساس ایجاد محدودیت " بر تقارن پارامترهای زمانی- مکانی راه رفتن در بیماران همی پارزی}, abstract_fa = {هدف: اختلالات تعادلی و راه رفتن از جمله عوارض حرکتی شایع به دنبال سکته مغزی می باشند. نتایج تحقیقات نشان می دهند که روشهای متداول فیزیوتراپی قادر نیستند بطور موثری این اختلالات را درمان نمایند، بنابراین لزوم انجام بررسیهای گسترده تر در مورد شناخت علل این عوارض و ارائه راهکارهای درمانی موثر ضروری به نظر می رسد. با توجه به نتایج موثر حرکت درمانی بر اساس ایجاد محدودیت در درمان اختلالات حرکتی اندام فوقانی بیماران همی پارزی، در این پژوهش هدف آن است که تاثیر "حرکت درمانی بر اساس ایجاد محدودیت" بر تقارن پارامترهای زمانی مکانی و سرعت راه رفتن در بیماران همی پارزی مورد بررسی قرار گیرد. روش بررسی: در این بررسی از نوع کارآزمایی بالینی شبه تجربی، (30 نفر) بیمار مبتلا به همی پارزی با دامنه سنی 60-40 سال شرکت نمودند. بیماران بطور تصادفی به دو گروه تقسیم شدند. گروه اول به روش " حرکت درمانی براساس ایجاد محدودیت "و گروه دوم به روش حرکت درمانی انبوه، بمدت 3 هفته تحت درمان قرار گرفتند. ارزیابیهای آزمایشگاهی بیماران شامل اندازه گیری سرعت سیکل راه رفتن و تقارن پارامترهای زمانی- مکانی راه رفتن (تقارن طول گامها، تقارن زمانهای فاز ایستا و نوسانی و تقارن زمانی کلی) بودند که قبل و پس از دوره درمان ثبت و مورد مقایسه قرار گرفتند. به علاوه میزان عدم تقارن در تحمل وزن نیز از طریق صفحه نیروی دوگانه مورد ارزیابی قرار گرفت. یافته ها: سرعت سیکل راه رفتن در هر دو گروه افزایش نشان داد (0/01=p و0/03 = p). در گروه اول قرینگی طول قدمها افزایش معنی دار نشان داد (0/02 = p). ضمنا، غیر قرینگی زمانی فاز نوسانی و غیرقرینگی زمانی کلی کاهش معنی دار نشان دادند (0/01=p). در گروه دوم، تنها غیر قرینگی زمانی فاز نوسانی کاهش معنی دار نشان داد (0/02 = p). بحث و نتیجه گیری : فیزیوتراپی به روش " حرکت درمانی بر اساس ایجاد محدودیت " با غلبه بر پدیده یادگیری در عدم استفاده و با اصلاح نقص در ارسال پیامهای حسی به سمت مراکز کنترل کننده حرکت، قادرست به نحو موثرتری در بهبود تقارن پارامترهای زمانی- مکانی راه رفتن، عمل کند.}, keywords_fa = {حرکت درمانی بر اساس ایجاد محدودیت,راه رفتن,پارامترهای زمانی- مکانی,همی پارزی}, url = {https://jpsr.mums.ac.ir/article_502.html}, eprint = {https://jpsr.mums.ac.ir/article_502_5c236747130cf6064b62743b86fe1bae.pdf} } @article { author = {Aghamohammadi-Kalkhoran, M and Rostamnejad, M and AfzaliFard, H}, title = {Risk factors for carpal tunnel syndrome: A case-control study}, journal = {Journal of Paramedical Sciences & Rehabilitation}, volume = {2}, number = {1}, pages = {49-54}, year = {2013}, publisher = {Mashhad University of Medical Siences}, issn = {2322-5238}, eissn = {2345-2730}, doi = {10.22038/jpsr.2013.505}, abstract = {Purpose: This study aimed to determine the risk factors for carpal tunnel syndrome in women. It was done in an effort to prevent the development of this neurological disease in women. Methods: A case - control study was performed on 132 women with carpal tunnel syndrome and 80 women without disease, with an age range of 18-60 years, referred to one of the physical therapy centers in Ardabil. Samples were selected randomly and the radial and ulnar nerve conduction standard tests were done. In order to collect data, a questionnaire that included common risk factors for carpal tunnel syndrome was used. Data analysis was performed by using t-test and chi-square test. Results: T-test showed statistically significant differences between cases and controls in the mean length and width of the wrist (p=0.001). Among the hormonal factors, diabetes in the case group was three times more than the control group. Furthermore, calculation of second chances coefficient for taking oral contraceptives showed that these drugs can be also among the risk factors for carpal tunnel syndrome. Based on the results, using cold water and washing clothes by hand in the patient group was significantly more than the control group (p=0.033) (p=0.011). Conclusion: Housekeeping, history of using oral contraceptives and diabetes can be the risk factors for carpal tunnel syndrome. Moreover, factors such as number of children, weight, length and width of the wrist and using cold water for washing were more common in patients. Understanding these factors can be an effective step in preventing this common problem in women.}, keywords = {Carpal tunnel syndrome,Risk factors,Physical factors,Women}, title_fa = {عوامل مستعدکننده سندرم تونل¬کارپ: یک مطالعه مورد-شاهدی}, abstract_fa = {هدف: مطالعه حاضر که با هدف تعیین عوامل مستعدکننده سندرم تونل ‌کارپ در زنان اردبیل انجام گرفت تلاشی در جهت پیشگیری از ابتلا به این بیماری شایع عصبی در زنان می‌باشد. روش بررسی: پژوهش حاضر، یک مطالعه مورد- شاهدی است که بر روی 132 زن مبتلا به سندرم تونل‌ کارپ و 80 زن غیرمبتلای 60-18 سال مراجعه ‌کننده به یکی از مراکز طب فیزیکی شهر اردبیل انجام گرفت. شرکت‌ کنندگان در مطالعه تحت آزمون‌های استاندارد هدایت عصبی رادیال و اولنار قرارگرفتند و سپس از یک پرسشنامه خودساخته که در برگیرنده عوامل خطرساز شایع سندرم تونل‌ کارپ بود برای جمع‌آوری اطلاعات استفاده گردید. تحلیل داده‌ها با استفاده از آزمون‌های تی‌ و کای‌دو انجام شد. یافته‌ ها: نتایج آزمون تی، اختلاف معنی‌دار آماری را بین دو گروه مورد و شاهد از نظر میانگین طول و پهنای مچ دست نشان داد (p=0.001). در بین عوامل هورمونی، بیماری دیابت در گروه بیمار، 3 برابر بیش از گروه شاهد بود. به‌علاوه، محاسبه ضریب شانس 2 در مورد مصرف داروهای خوراکی ضدبارداری نشان داد که این داروها نیز می‌توانند از جمله عوامل خطرساز  برای سندرم تونل کارپ باشند. همچنین براساس نتایج یافت شده، شستن لباس با دست (0/033 =p ) و استفاده از آب سرد (p=0/011) در گروه بیمار به طور معنی‌ داری بیش از گروه شاهد بود. بحث و نتیجه‌ گیری: خانه‌ داری، سابقه مصرف قرص‌های ضد بارداری خوراکی و دیابت می‌توانند از عوامل مستعدکننده سندرم تونل‌ کارپ باشند. ضمن اینکه عواملی همچون تعداد فرزندان، وزن، طول و ‌پهنای مچ دست و استفاده از آب سرد برای شستشو نیز در افراد مبتلا بیشتر دیده شد. شناخت این عوامل، می‌تواند گام موثری در پیشگیری از این مشکل شایع در زنان باشد.}, keywords_fa = {سندرم تونل کارپ,عوامل مستعدکننده,شاخص¬های فیزیکی,زنان}, url = {https://jpsr.mums.ac.ir/article_505.html}, eprint = {https://jpsr.mums.ac.ir/article_505_e8e25d8c2a5e7799e71c6e583d0725a6.pdf} } @article { author = {Hassan Abadi, H and Azhari, A and Rahimi, H.R}, title = {Polyneuropathy in gasoline addiction, a report of three cases}, journal = {Journal of Paramedical Sciences & Rehabilitation}, volume = {2}, number = {1}, pages = {55-62}, year = {2013}, publisher = {Mashhad University of Medical Siences}, issn = {2322-5238}, eissn = {2345-2730}, doi = {10.22038/jpsr.2013.506}, abstract = {The polyneuropathy caused by chronic Gasoline Sniffing is reported to be a gradually progressive, symmetric, sensorimotor polyneuropathy. The report of gasoline sniffing by three 12, 16 and18 years old brothers (Respectively 5, 8 and 11 years of gasoline inhalation addiction) that referred with  peripheral neuropathy was studied. The conditions were characterized by relatively small reduction in nerve conduction velocity (depending on the severity of nerve involvement) and to some degree in all four limbs with moderate to severe sensory and motor involvement, lower limbs had worse conditions than upper limbs. The neuropathy was attributed to the N-hexane and tetraethyl, the lead components of gasoline. Educational efforts about the dangers of gasoline sniffing are essential.}, keywords = {Polyneuropathy,Gasoline sniffing,Electrodiagnostic,Nerve conduction velocity,Electromyography}, title_fa = {گزارش سه مورد پلی نوروپاتی در اعتیاد با بنزین}, abstract_fa = {خلاصه: پلی نوروپاتی ناشی از استنشاق مزمن بنزین با پلی نوروپاتی به تدریج پیشرونده، متقارن، حسی حرکتی گزارش شده است ما گزارش اعتیاد استنشاقی به بنزین توسط سه برادر 12، 16، 18 ساله ( به ترتیب 5، 8 و 11 سال سابقه اعتیاد داشتند) که با نوروپاتی محیطی مراجعه کرده اند را بررسی کردیم. این وضعیت با تغییرات واضح و وسیع در الکترومیوگرافی و ارتفاع (آمپلی تود) پاسخ های حسی وحرکتی (بسته به شدت درگیری اعصاب) و کاهش نسبتاً مختصر سرعت هدایت عصبی و در محدوده تقریباً نرمال و تاخیر انتهایی (distal latency) مشخص شد، که این تغییرات ارتباط مستقیم با طول مدت اعتیاد به بنزین داشت و تغییرات در قسمت دیستال اندامهای تحتانی شدیدتر از اندامهای فوقانی بود. نوروپاتی به علت وجود اِن- هگزان و تترا اتیل سرب در بنزین نسبت داده شد. تلاش های آموزشی در مورد خطرات ناشی از اعتیاد استنشاقی به بنزین ضروری است.}, keywords_fa = {پلی نوروپاتی,اعتیاد استنشاقی به بنزین مزمن,الکترودیاگنوزیس,سرعت هدایت عصبی,الکترومیوگرافی}, url = {https://jpsr.mums.ac.ir/article_506.html}, eprint = {https://jpsr.mums.ac.ir/article_506_d4cad8fcad69a66202e96af6d1122d6d.pdf} }