<?xml version="1.0" encoding="utf-8"?>
			<journal>
			<title>Journal of Paramedical Sciences &amp; Rehabilitation</title>
			<title_fa>فصلنامه علمی- پژوهشی علوم پیراپزشکی وتوانبخشی</title_fa>
			<short_title></short_title>
			<subject>Medical Sciences</subject>
			<web_url>https://jpsr.mums.ac.ir/</web_url>
			<journal_hbi_system_id>0</journal_hbi_system_id>
			<journal_hbi_system_user></journal_hbi_system_user>
			<journal_id_issn>2322-5238</journal_id_issn>
			<journal_id_issn_online>2345-2730</journal_id_issn_online>
			<journal_id_pii></journal_id_pii>
			<journal_id_doi></journal_id_doi>
			<journal_id_iranmedex></journal_id_iranmedex>
			<journal_id_magiran></journal_id_magiran>
			<journal_id_sid></journal_id_sid>
			<journal_id_nlai></journal_id_nlai>
			<journal_id_science></journal_id_science>
			<language>fa</language>
			<pubdate>
				<type>jalali</type>
				<year>1401</year>
				<month>3</month>
				<day>1</day>
			</pubdate>
			<pubdate>
				<type>gregorian</type>
				<year>2022</year>
				<month>6</month>
				<day>1</day>
			</pubdate>
			<volume>11</volume>
			<number>1</number>
			<publish_type>online</publish_type>
			<publish_edition>1</publish_edition>
			<article_type>fulltext</article_type>
			<articleset><article>
				<language>en</language>
				<article_id_issn></article_id_issn>
				<article_id_issn_online></article_id_issn_online>
				<article_id_pubmed></article_id_pubmed>
				<article_id_pii></article_id_pii>
				<article_id_doi></article_id_doi>
				<article_id_iranmedex></article_id_iranmedex>
				<article_id_magiran></article_id_magiran>
				<article_id_sid></article_id_sid>
				<title_fa>تاثیر تونومتری اپلانیشن بر پارامترهای سگمان قدامی چشم ‏</title_fa>
				<title>The Effect of Applanation Tonometry on Parameters of the Anterior Segment of the ‎Eye</title>
				<subject_fa></subject_fa>
				<subject></subject>
				<content_type_fa>مقاله پژوهشی</content_type_fa>
				<content_type>Original Article</content_type>
				<abstract_fa><![CDATA[هدف:انجام تونومتری گلدمن یکی از ارزیابی های قبل عمل کاتاراکت می باشدکه به صورت تماس مستقیم با قرنیه، فشار داخل چشمی را اندازه می گیرد. هدف این مطالعه بررسی تاثیر تونومتر اپلانیشن گلدمن بر عمق اتاق قدامی چشم و مقادیر کراتومتری بدست آمده با پنتاکم است.روش بررسی:این مطالعه مقطعی بر روی 15 فرد کاتاراکت با رنج سنی 42 تا 78 سال در بیمارستان چشم پزشکی الزهرا زاهدان انجام گردید. در ابتدا عمق اتاق قدامی، آسفریسیتی، کراتومتری فلت قدامی وخلفی، کراتومتری استیپ قدامی و خلفی، کراتومتری پریفرال و آستیگماتیسم قدامی و خلفی با استفاده از پنتاکم اندازه گیری و ثبت گردید. سپس تونومتری با استفاده از تونومتر اپلانیشن گلدمن انجام گردید. اندازه گیری های پنتاکم در فاصله یک دقیقه و ده دقیقه پس از انجام تونومتری نیز ثبت گردید. داده ها با استفاده از آزمون آنالیز واریانس با اندازه گیری تکراری آنالیز گردید و مقدار p کمتر از 0/05 به عنوان سطح معنی داری آزمون در نظر گرفته شد.یافته ‌ها:آنالیز داده های بدست آمده از افراد دارای کاتاراکت نشان داد که در تمامی پارامترهای اندازه گیری با پنتاکم تفاوت معنی داری قبل، یک دقیقه و ده دقیقه پس از انجام تونومترگلدمن وجود نداشت (0/05&lt;p).نتیجه گیری:یافته های این مطالعه نشان داد که تونومتری گلدمن تأثیر معنی داری بر عمق اتاق قدامی و انحنای قرنیه در بیماران دارای کاتاراکت ندارد. بنابراین تونومتری گلدمن می تواند در بیماران دارای کاتاراکت در همان جلسه ارزیابی پارامترهای قرنیه ای انجام شود.]]></abstract_fa>
				<abstract><![CDATA[Purpose:Goldman tonometry is one of the preoperative techniques for cataract surgery that measures intraocular pressure by direct contact with the cornea. The aim of this study was to evaluate the effect of Goldman tonometer on the anterior chamber depth (ACD) and keratometric values using Pentacam HR.Methods:This cross-sectional study was performed on 15 cataract patients with age range of 43 to 78 years in Al-Zahra Ophthalmology Hospital in Zahedan, Iran. Initially, ACD, asphericity, anterior and posterior flat keratometry, anterior and posterior steep keratometry, peripheral keratometry, and anterior and posterior astigmatism were measured using Pentacam HR. Then tonometry was performed using Goldman applanation tonometer. Pentacam measurements were also recorded one minute and ten minutes after tonometry. Data were analyzed using repeated measures of ANOVA and P value less than 0.05 was considered as a significant level of the test.Results:Results showed no significant difference in all measurement parameters with Pentacam before, one minute and ten minutes after Goldman tonometer (p&gt;0.05).Conclusion:The findings of this study showed that Goldman tonometry has no significant effect on anterior chamber depth and corneal curvature in cataract patients. Therefore, Goldman tonometry can be performed in cataract patients in the same session of corneal parameter evaluation.]]></abstract>
				<keyword_fa>تونومتری اپلانیشن گلدمن، پنتاکم، عمق اتاق قدامی</keyword_fa>
				<keyword>Applanation Goldmann tonometry, Pentacam, Anterior chamber depth</keyword>
				<start_page>21</start_page>
				<end_page>27</end_page>
				<web_url>https://jpsr.mums.ac.ir/article_20254.html</web_url>
			<author_list><author>
				<first_name>M</first_name>
				<middle_name></middle_name>
				<last_name>Mahjoob</last_name>
				<suffix></suffix>
				<first_name_fa>منیره</first_name_fa>
				<middle_name_fa>منیره</middle_name_fa>
				<last_name_fa>محجوب</last_name_fa>
				<suffix_fa></suffix_fa>
				<email>mahjoob_opt@yahoo.com</email>
				<code>87581</code>
				<coreauthor>No</coreauthor>
				<affiliation>Department of Optometry, School of Rehabilitation, Zahedan University of Medical Sciences, Zahedan, Iran</affiliation>
				<affiliation_fa>استادیار گروه اپتومتری، دانشکده توانبخشی، دانشگاه علوم پزشکی زاهدان، زاهدان، ایران</affiliation_fa>
				 </author><author>
				<first_name>N</first_name>
				<middle_name></middle_name>
				<last_name>Nakhjavanpour</last_name>
				<suffix></suffix>
				<first_name_fa>ندا</first_name_fa>
				<middle_name_fa>ندا</middle_name_fa>
				<last_name_fa>نخجوان پور</last_name_fa>
				<suffix_fa></suffix_fa>
				<email>neda.nakhjavanpoor@gmail.com</email>
				<code>87582</code>
				<coreauthor>No</coreauthor>
				<affiliation>Department of Optometry, School of Rehabilitation, Zahedan University of Medical Sciences, Zahedan, Iran</affiliation>
				<affiliation_fa>مربی گروه اپتومتری، دانشکده توانبخشی، دانشگاه علوم پزشکی زاهدان، زاهدان، ایران</affiliation_fa>
				 </author><author>
				<first_name>T</first_name>
				<middle_name></middle_name>
				<last_name>Rakhshandadi</last_name>
				<suffix></suffix>
				<first_name_fa>طاهره</first_name_fa>
				<middle_name_fa>طاهره</middle_name_fa>
				<last_name_fa>رخشان دادی</last_name_fa>
				<suffix_fa></suffix_fa>
				<email>t.rakhshandadi@yahoo.com</email>
				<code>87583</code>
				<coreauthor>Yes</coreauthor>
				<affiliation>Department of Optometry, Refractive Error Research Center, Mashhad University of Medical Sciences, Mashhad, Iran</affiliation>
				<affiliation_fa>دانشجوی دکترای تخصصی اپتومتری، مرکز تحقیقات عیوب انکساری چشم، دانشگاه علوم پزشکی مشهد، مشهد، ایران</affiliation_fa>
				 </author></author_list>
				</article>
			</articleset>
			</journal>